B Deck

BW-36, Wide Rib, 1.5B

Get a Quote
B-deck profile illustratration

B Deck

B Deck: Our Most Popular Roof Deck

In Stock – Fast Shipping or Same Day Pickup

We offer quality roof deck at competitive prices. B Deck is the most common structural roof deck and provides an economical and easy to install choice.

CSM Metal Deck stocks and manufactures B, BI, BV, and BIV types of roof deck in 22, 20, 18, and 16 gauge. Typically B Decking is the ideal solution for short to medium span applications in roof, canopies, and awning construction. CSM Metal Deck’s B Deck supports construction spans from 1 foot to 11 feet in distance, depending upon the gauge and back-span condition (single, double, triple).

We ship nationwide from our Houston, TX metal deck warehouse. Please complete the quote form below or call us at 1-866-553-0373 to request a custom quote for your construction project.

Engineering

Download as PDF

Table of Section Properties

table of section properties b-deck

Note: All section properties and ASD flexural strengths are calculated in accordance with ANSI/SDI RD-2017, AISI S100-2012 and AISI S100-2016. 

Table of Shear and Web Crippling

table of shear and web crippling b-deck

Note: All section properties and ASD flexural strengths are calculated in accordance with ANSI/SDI RD-2017, AISI S100-2012 and AISI S100-2016. 

Table of Allowable Uniform Downward Loads, ASD (PSF)

Table of Allowable Uniform Upward Loads, ASD (PSF)

Allowable Uniform Upward Loads, ASD (PSF) b-deck

Table of Uniform Superimposed Service Load that Causes L/240 Deflection (PSF)

Uniform Superimposed Service Load that Causes L:240 Deflection (PSF) b-deck

Note: For loads that cause L/120 Deflection, multiply by 2.0. For loads that cause L/180 Deflection, multiply by 1.5. For loads that cause L/360 Deflection, multiply by 0.667.

Table of Maximum Construction and Cantilever Spans

Maximum Construction and Cantilever Spans b-deck

Notes: (1) All construction load spans are calculated using a 200 pound service load on a 1 foot width of deck, in accordance with ANSI/SDI RD-2017. (2) All cantilever construction load spans are calculated using a 200 pound service load on a 1 foot width of deck and a 10 psf uniform distributed load, in accordance with ANSI/SDI RD-2017. 

Get a Quote Download as PDF

Installation

Download as PDF

Roof Deck Installation

CSM steel roof deck shall be installed by qualified and experienced workers. Roof deck panels shall be placed in accordance with approved erection drawings. End laps shall be a nominal 2” and positioned over supports. A snap chalk line shall be used at reasonable intervals to assure proper alignment of deck panels.

Position the first sheet as noted on the drawing with the upstanding leg of the sheet away from the wall.

Overlap roof deck sheets end to end maintaining alignment. When one row is placed end to end, begin another, making alignment adjustments if necessary. Do not use unfastened deck as a work or storage area.

All sheets are furnished with square ends. All openings in the roof deck which are shown on the erection drawings and which are less than 25 square feet in area, as well as skew cuts, shall be field cut by the deck erector. Openings not shown on the erection drawings such as those required for stack, conduits, plumbing, vents, etc., shall be cut (and reinforced if necessary) by the trades requiring the openings.

Attachment

Roof deck sheets shall be attached as soon as possible after placement and all sheets placed shall be attached at the end of each working day. Electric arc welding is the best and most economical method for attaching Wheeling steel roof deck to structural supports. Welder shall follow close to the placement crew.

All welds are to be made from the top of the deck down through the bottom flange of the ribs. Welds shall penetrate and attach all thicknesses of material to the structural supports. Care shall be exercised on the selection of the electrodes to provide positive attachment and to prevent high amperage blowholes. Puddle welds shall be at least 5/8” diameter or elongated puddle welds with an equal perimeter. Fillet welds, when used, shall be at least 1” long. Roof deck shall be welded to structural supports with the following pattern:

1-1/2” Deck: Ends of deck to be welded to supports at 12 inches on center maximum and 18 inches on center maximum at intermediate supports.

3” Deck: Deck to be welded to all supports at 8 inches on center.

4-1/2”, 6”, 7-1/2” Deck: Deck to be welded to all supports at 12 inches on center.

Various mechanical fastening systems other than welding are recognized as viable anchoring methods provided that they are reviewed, approved or specified by the project designer. These include but are not limited to screws, powder-activated or pneumatically driven fasteners.

When spans exceed 5’-0”, side laps shall be fastened together at a maximum spacing of 36 inches on center.

Site Storage

Deck not promptly erected shall be stored off the ground with one end elevated and protected from the elements with a tarpaulin or other weather-proof covering, ventilated to avoid condensation. Reference SDI Manual of Construction Site Storage and Protection.

Site Storage

All steel to be used in CSM steel roof deck shall be galvanized or given a protective shop coat of primer paint. The paint coating is considered only a primer and is intended to protect the steel for only a reasonable period of time exposed to normal atmospheric conditions and shall be considered an impermanent and provisional coating. Galvanized finish in G-60 or G-90 coating is desirable in high moisture atmospheric conditions.

CSM Products & Solutions shall not be responsible for the cleaning of the underside of the steel roof deck to ensure bond of the sprayed-on fireproofing. Adherence of fireproofing material is dependent on many variables. The adhesion or adhesive ability of fireproofing material is the responsibility of the fireproofing applicator and fireproofing manufacturer.

Get a Quote Download as PDF

Accessories

Download as PDF

Recessed Sloped Sump Pan Diagram

Recessed Sump Pan diagramRecessed Sump Pan diagram

Flate Plate diagram

4 inch diagramRidge and Valley platesRubber closures diagram

 

 

Get a Quote Download as PDF

Details

Download as PDF

Flush Eave diagramridge beam diagramEave diagramRoof Overhang diagramInterior Wall diagramparapet diagramFlush Eave diagramopen framing detail diagram

Metal Roofing DiagramCurved roof diagram

Get a Quote Download as PDF

Get a Quote

  • For finish other than Galvanized, state your preference in the “Special Requests” field below
  • Quote purpose

  • Delivery information

  • MM slash DD slash YYYY
  • Send quote to

  • This field is for validation purposes and should be left unchanged.

Primary Sidebar

About CSM Metal Deck

At CSM we know metal deck. We have been supplying metal deck throughout the country for over 50 years. Choose from metal roof deck, composite deck and form deck, in a variety of depths, widths and gauges.

  • This field is for validation purposes and should be left unchanged.
Looking for a lump sum quote? Send your project’s drawings and specifications to bids@metaldecking.com

Recent Articles

  • Types of Roof Deck
  • Rolled-In Hanger Tabs vs. Piercing Hanger Tabs
  • CSM Metal Deck is Now Listed on ARCAT

Footer

CSM Metal Deck

8660 Lambright Road
Houston, TX 77075
1-866-553-0373
info@metaldecking.com

  • Privacy Policy

A Certified SDI Member

Steel Deck Institute

Copyright © 2023 CSM Products and Solutions, LLC

  • Privacy Policy